KEY FEATURES
Measures All Important Quantities…
…and More
- Full-Power On-Line Measurement
- High Accuracy, High Dynamic Range
- Compact Design
- Intelligence Inside
- RS-232 Interface to External Controller
- Windows Control, Visualisation and Data Logging Software
- Drives Autotuning System
BASIC FEATURES
Primarily measured quantities:
- Reflection coefficient (magnitude and phase)
- Incident power
- Frequency
- Internal temperature for accuracy enhancement
- Measurement under full-power operating conditions
- 20 dB dynamic range of working power
- WR340 waveguide interface (R-26, WG-9A) for 2.45 GHz ISM band
- WR975 waveguide interface (R-9) for 900MHz ISM band
- Contains single-board computer for fast data acquisition and processing
- Integrates easily into existing computer-based instrumentation and monitoring
systems
- In conjunction with the TriStun tuner enables automatic impedance matching of timevarying
loads.
SOFTWARE FEATURES
Microsoft Windows® environment
Display formats:
- Magnitude and phase of reflection coefficient
- Return loss, VSWR
- Incident, reflected and absorbed powers (in watts or dB)
- Polar diagram, Smith chart, Rieke diagram
- Simultaneous display in various formats as well as numerically
- Unlimited data logging of all quantities of interest
- Extensive on-line help
1) Actual maximum operating power is fixed according to customer’s demand not to exceed 30 kW. Actual minimum operating power is then 20 dB less or 1 W, whichever is greater.
Das Hot Measurement System ist auch für 896, 915, 922MHz / R9-Hohlleiter lieferbar.
_________________________________________________________________________________________________
1) Actual maximum operating power is fixed according to customer’s demand not to exceed 30 kW. Actual minimum operating power is then 20 dB less or 1 W, whichever is greater.
2) Generally, the match is improved for loads outside of the tuning range (e.g. VSWR=30 drops below 5).